Page 13
Technical Specification
Trip Range:
75dB to 112.5dB in 2.5dB steps switch selectable
+5dB calibration control (factory set)
Trip Time:
5 seconds to 30 seconds user adjustable (potentiometer)
When tripped unit automatically resets after trip time
Frequency Weighting:
A weighted in accordance with BS EN 60651 Type 2
Time Weighting:
Slow 1000mS in accordance with BS EN 60651 Type 2
Microphone:
Type: Electric Condenser
Sensitivity: -65dB (0dB = 1V/μBar 1000Hz)
S/N ratio: 40dB
Calibration:
Factory Calibrated
Illumination:
Two 8W fluorescent tubes
Temperature:
Operating range: -10 to 50C
Effect of temperature: <0.5dB from -10 to 50C
Humidity:
Effect of Humidity: <0.5dB from 30% RH to 90% RH
Overall Dimensions and Weight:
520W x 200H x 120D mm
4.2Kg